Discover why you should consider transitioning from air to liquid cooling, what the process involves – and how the benefits far outweigh the initial investment.
Air cooling has been the stalwart of data centre cooling solutions for over half a century now. However, as the demand for higher rack power density increases, relying solely on air cooling is becoming increasingly impractical, costly and inefficient.
It’s why more and more data centre owners are considering transitioning to liquid cooling solutions to future proof their facilities and it is predicted to grow substantially over the next decade [1].
Pros (and cons)
Perhaps we shouldn’t be surprised at such growth predictions. After all, as a data centre stakeholder, you’ll already know that liquids are more efficient at conducting heat than air, able to absorb and transfer heat at a greater rate. You’ll also likely know the many far-reaching benefits of liquid cooling from improved scalability, performance and energy efficiency through to reduced running costs and noise levels.
However, the concept of introducing liquid cooling solutions into an existing data centre often gives owners ‘pause for thought’ because of the costs involved. This hesitation is compounded further by the complexity of a retrofit, which requires several processes to be undertaken including:
- Procuring and installing the liquid cooling equipment
- Decommissioning and stripping out existing conventional cooling equipment
- Making modifications to existing services to accommodate liquid cooling
- Upgrading infrastructure as additional power may be required to cope with the higher cooling demands
- Upgrading the water supply-to-site depending on the heat rejection method.
Reaping rewards
To offset such concerns, you should first consider the significant financial benefits of making the switch both in the short and long term. Most important is that you will see far greater energy efficiency from day one, which means a substantial reduction in electricity costs that, over time, will offset the cost of your initial investment.
Remember, a conventional air-based system such as a Fan Wall, CRAH or CRAC unit uses vast amounts of energy to cool and move the volume of air needed to keep IT equipment cool. Now compare this to a liquid cooling system such as direct-to-chip, which cools the IT equipment at the heat source, therefore using far less energy to cool the same IT loads.
Also, while not always deemed as an accurate reflection of a data centre’s efficiency, the PUE (power usage effectiveness) remains a common metric for measuring the energy efficiency of a centre. By implementing liquid cooling, you should expect to see a lower PUE compared to an air-cooled equivalent. However, it is important to understand this may not always be the case, it isn’t unusual for liquid cooling systems such as direct-to-chip for high density systems to require lower coolant temperatures than the traditional air cooled system it is replacing; meaning the existing heat rejection plant operating temperatures may not be suitable, or may need to operate at higher temperatures or at a different temperature delta, which potentially has a negative impact on the overall PUE due to the increase energy use for heat rejection plant. It is important to take a holistic approach when considering implementing liquid cooling to ensure you optimise the cooling system to maximise its operating efficiency.
Sustainable business
Size also matters as liquid cooling plants are typically more compact compared to conventional air-cooled methods. If you are fitting retrospectively, this could free up a substantial amount of space within your existing facility that, in turn, could be used to increase available IT capacity – and service more customers. By making the switch, you’ll also reduce your carbon footprint, massively improving the sustainability of your business and reducing its environmental impact.
Those are the top line benefits – but how do data centre owners begin exploring liquid cooling retrofitting? First, it’s important to understand the different types of solutions available. At J Dunton Associates, the most popular options we are consulted on are based around liquid cooling hybrid systems such as direct-to-chip in combination with a conventional air-cooled system, or direct-to-chip and rear-door. For a full breakdown of the different liquid/immersion technologies available, check our in-depth guide here.
Accurate assessments
While technologies vary, there are fundamental questions that you do need to answer about your current infrastructure to determine whether it is suitable for liquid cooling retrofits in the first instance. These include:
- Power: Assess if there is any spare capacity available and explore options for upgrading power if more is required for the transition.
- Existing systems: Determine if there is potential to connect into the existing chilled water services. Crucially, are the current operating temperatures of the heat rejection plant compatible with the liquid cooled equipment’s requirements?
- Space: Check if there is enough physical space to run new pipework and cables. Typically, liquid cooling is used with high density racks that are heavier, so some load calculations need to be conducted to determine whether the existing floor structure is suitable.
Robustness as standard
Resilience and redundancy strategies are also vital to a successful liquid cooling system retrofit. You should approach these as you would a conventional air-cooled system. Typically, you will retain the current heat rejection plant – which should already have redundancy built in – and any liquid cooling plant introduced must also be designed to meet the required redundancy levels.
If you are implementing cooling distribution units, these must have redundancy as well. The pipework to and from these units should also be configured with diverse routes. Finally, there needs to be a clean area to store spare parts plus additional fluid to guarantee your liquid cooling plant is always operational.
Helping hand
Ultimately, the retrofitting process does pose a significant challenge. It’s why owners are serious about making the switch partner to partner with a specialist advisor such as J Dunton Associates to ensure all the necessary work is carried out diligently. Working in partnership with liquid cooling technology providers, we already design our own data centre systems to be ‘Liquid Cooling Ready’, future-proofing systems for any potential change, all while ensuring there is minimal impact on the data centre rack and equipment installation.
We can also help analyse your existing air-cooled infrastructure to assess what work will be required for a retrofit. With our multi-disciplined, mission-critical team offering over 15 years of experience in this specialist field, if you do decide to team up, you will find your retrofit – and your future – are in the best possible hands.